OM POWER OM4001A
Fully automatic amplifier from 160 to 10 meters, over 4 kW SSB/CW, 3 kW key down RTTY/DIGI
* Delivery usually within 7 working days *
The OM Power OM4001A is an automatic power amplifier, designed for use on all amateur shortwave bands from 1.8 to 29.7 MHz (including WARC bands) and all modes. It is equipped with two FU728F ceramic tetrode tubes.
Advantages of OM4001A:
Full compatibility with
- ICOM
- YAESU
- ELECRAFT
- Ten-Tec Orion
- Kenwood
- Icom transceiver protocol using microHAM devices - CI-V output (MK II, MK2R, MK2R+, etc.)
- Flex Radio Series 6xxx
- Apache Labs Anan
Sensitive RF band and frequency switching, for use with radios that do not have CAT
Automatic switching between bands
Automatic tuning to the band according to segments
Automatic band-pass filter switching - BAND DATA output compatible with YAESU radios (BCD code)
Automatic switching of antenna switches: maximum number of antennas is 10, controlled by BCD output code
Remote control via PC Windows application
OM4001A specification:
Frequency coverage: Amateur bands 1.8 - 29.7 MHz, including WARC
Output power: 4000+ W in SSB and CW on HF bands,
3000 W in RTTY and DIGI modes
Input power: Typically 40 to 60 W for maximum output power
Input impedance: 50 Ohm, VSWR <1.5:1
Power gain: 17 dB
Output impedance: 50 Ohm unbalanced
Maximum output SWR: 3:1
SWR protection: Automatic switch to STBY, when reflected power is 350 W or higher
Intermodulation distortion: -32 dB below nominal output
Harmonic suppression: <-50 dBc
Tubes: 2x FU728F ceramic tetrode
Cooler: Centrifugal blower + Axial blower
Automatic tuning response speed: less than 0.5 in the same BAND, less than 3 if not in BAND
Power supply: Switchable 2 x 220/230/240V - 50 Hz single or two-phase
Transformers: 2 pcs of 3kVA toroidal transformer
Dimensions: 485 x 200 x 455 mm (width x height x depth)
Weight: 46 kg
Protection circuits: - Too high VSWR
- Anode current too high
- Anode voltage error
- Screen current too high
- Screen voltage error
- Grid current too high
- Mains voltage error
- Heater voltage error
- PA mistuning
- Too high temperature
- Soft start to protect your fuses
- "Ignition block" when amplifier is open
Indications: 4.3" color touch screen display
Features: High level of protection
Fault and warning memory, easy maintenance
Automatic anode current setting (BIAS): no need to adjust manually after replacing tubes
Three programmable axial fan working modes
Full QSK with silent relay
Many operating parameters to be displayed
The smallest and lightest 4000 W power amplifier on the market
LAN connection
The power amplifier is interfaced to the LAN via XPORT produced by Lantronix (type XP1001000-05R). More information can be found at www.lantronix.com.
The default factory settings of XPORT are:
IP Address: 192.168.1.222
Mask: 255.255.255.0
Gateway: 192.168.1.1
These are strictly default settings. Any of these can be changed by accessing the XPORT Web GUI via your Web browser. It is not recommended to change other parameters of the XPORT interface as loss of communication can be caused by this. There is no default username or password. It is strongly recommended to secure the web interface with a username and password.
Special software is required for remote control and monitoring over LAN. It is available for free, it can be downloaded from the following address: