General features:
- Automatic voltage discharge
- Max/Min function
- Type K Thermocouple
- Auto power off
- Large backlit LCD display
- CAT III 1000V, CAT IV 600V

- IP67
- Dimensions: 220 x 96.5 x 60.5mm
- Weight: 631g
- Complete with: Hard case, temperature probe, USB cable, software, manual

| DC VOLTAGE | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 400mV | 0.01mV | ±(0.06% rdg +4 dgt) | |||
| 4V | 0.0001V | ||||
| 40V | 0.001V | ||||
| 400V | 0.01V | ||||
| 1000V | 0.1V | ±(0.1% rdg +5 dgt) | |||
| AC VOLTAGE | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 50 to 1000Hz | |||||
| 400mV | 0.1mV | ±(1.0% rdg +7 dgt) | |||
| 4V | 0.001V | ||||
| 40V | 0.01V | ||||
| 400V | 0.1V | ||||
| 1000V | 1V | ±(1.0% rdg +5 dgt) | |||
| AC+DC VOLTAGE | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 400mV | 0.1mV | ±(1.0% rdg +7 dgt) (50/60HZ) | |||
| 4V | 0.001V | ||||
| 40V | 0.01V | ||||
| 400V | 0.1V | ||||
| 1000V | 1V | ||||
| Note: all AC voltage ranges refer to the range interval between 5% and 100% | |||||
| DC CURRENT | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 400µA | 0.01µA | ±(1.0% rdg +3 dgt) | |||
| 4000µA | 0.1µA | ||||
| 40mA | 0.001mA | ||||
| 400mA | 0.01mA | ||||
| 10A | 0.001A | ||||
| (20A: maximum 30 sec. with reduced accuracy) | |||||
| AC CURRENT (AC+DC) | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 50 to 1000Hz | |||||
| 400µA | 0.1µA | ±(1.5% rdg +7 dgt) | |||
| 4000µA | 1µA | ||||
| 40mA | 0.01mA | ||||
| 400mA | 0.1mA | ||||
| 10A | 0.01A | ||||
| AC+DC CURRENT | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 400µA | 0.1µA | ±(1.5% rdg +7 dgt) | |||
| 4000µA | 1µA | ||||
| 40mA | 0.01mA | ||||
| 400mA | 0.1mA | ||||
| 10A | 0.01A | ||||
| (20A: maximum 30 sec. with reduced accuracy) Note: all AC voltage ranges refer to the range interval between 5% and 100% | |||||
| RESISTANCE | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 400 Ohm | 0.1 Ohm | ±(0.3% rdg +9 dgt) | |||
| 4 kOhm | 0.0001 kOhm | ±(0.3% rdg +4 dgt) | |||
| 40 kOhm | 0.001 kOhm | ||||
| 400 kOhm | 0.01 kOhm | ||||
| 4 MOhm | 0.001 MOhm | ||||
| 40 MOhm | 0.001 MOhm | ±(2.0% rdg +10 dgt) | |||
| CAPACITANCE | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 40 nF | 0.001 nF | ±(3.5% rdg +40 dgt) | |||
| 400 nF | 0.01 nF | ±(3.5% rdg +10 dgt) | |||
| 4 µF | 0.0001 µF | ||||
| 40 µF | 0.001 µF | ||||
| 400 µF | 0.01 µF | ||||
| 4000 µF | 0.1 µF | ±(5% rdg +10 dgt) | |||
| 40 mF | 0.001 mF | ||||
| FREQUENCY (electronic) | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 40 Hz | 0.001 Hz | ±(0.1% rdg +1 dgt) | |||
| 400 Hz | 0.01 Hz | ||||
| 4 kHz | 0.0001 kHz | ||||
| 40 kHz | 0.001 kHz | ||||
| 400 kHz | 0.01 kHz | ||||
| 4 MHz | 0.0001 MHz | ||||
| 40 MHz | 0.001 MHz | ||||
| 100 MHz | 0.01 MHz | Unspecified | |||
|
Sensitivity: 0.8V rms min. from 20% to 80% duty cycle and <100kHz; 5Vrms min from 20% to 80% duty cycle and > 100kHz. | |||||
| FREQUENCY (electrical) | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 40.00 Hz - 10 kHz | 0.01 Hz - 0.001 kHz | ±(0.5% rdg) | |||
| Sensitivity: 1V rms | |||||
| Duty Cycle | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| 0.1 - 99.90% | 0.01% | ±(1.2% rdg +2 dgt) | |||
|
Pulse Width: 100 µs - 100ms Frequency: from 5 Hz to 150 kHz | |||||
| TEMPERATURE (type K) | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| -50 to 1000°C | 0.1°C | ±(1.0% rdg +2.5°C) | |||
| -58 to 1832°F | 0.1°F | ±(1.0% rdg +4.5°F) (probe accuracy not included) | |||
| 4-20mA% | |||||
| RANGE | RESOLUTION | ACCURACY | |||
| -25 to 125% | 0.01% | ±50 dgt | |||
| 0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125% | |||||
| MEG OHMS | |||||
| Terminal Voltage | RANGE | RESOLUTION | ACCURACY | Test Current | Short Circuit Current |
| 125V (0% - +10%) | 0.125 - 4.000 MOhm | 0.001 MOhm | +(2%+10) | 1mA at 125 kOhm load | < 1mA |
| 4.001 - 40.00 MOhm | 0.01 MOhm | +(2%+10) | |||
| 40.01 - 400.0 MOhm | 0.1 MOhm | ||||